<p>Please note: The replacement process varies from Roller 20/64 to Roller 100/150/300 <br> </p>
<p><span style='font-size: 16px;'><strong>Roller 20/64 - </strong></span></p>
<p><span style='font-size: 14px;'><strong>1. Remove the Existing Drive Unit (EDU) from the tube. </strong></span></p>
<p>Roller 20 and Roller 64 drives are pressure fit into the tube and do not utilize screws to secure the drive in the tube.</p>
<p>a. Using a flat head screwdriver, gently start to pry the drive out. </p>
<p><img alt='image.png' src='https://lutron.my.salesforce-sites.com/publicknowledge/servlet/rtaImage…;
<p>b. Once the drive is pried out of the tube, grab it by hand and remove it from the tube. </p>
<p><img alt='image.png' src='https://lutron.my.salesforce-sites.com/publicknowledge/servlet/rtaImage…;
<p><span style='font-size: 14px;'><strong>2. Insert the new/existing EDU into the new/existing tube making sure it is fully seated. <br>3. Reset Upper and Lower Limits</strong></span></p>
<p> </p>
<p><span style='font-size: 14px;'><strong> </strong></span><span style='font-size: 16px;'><strong>R100/150/300 - </strong></span></p>
<p><span style='font-size: 14px;'><strong>1. Remove the existing EDU (Electronic Drive Unit) from the tube </strong></span></p>
<p>a. Remove the 2 screws securing the shade bracket to the drive. </p>
<p> <img alt='image.png' src='https://lutron.my.salesforce-sites.com/publicknowledge/servlet/rtaImage…;
<p>b. Remove the 3 screws that secure the drive in the tube. The drive will need to be energized and rotated so each screw is accessible. </p>
<p><img alt='image.png' src='https://lutron.my.salesforce-sites.com/publicknowledge/servlet/rtaImage…;
<p>NOTE: If the drive will not power up, the drive end will need to be cut or broken off to gain access to the 3 screws. This will damage the drive but is an acceptable practice in this situation. Please keep and send all parts in case an RMA is issued. </p>
<p><span style='font-size: 14px;'><strong>2. Install the EDU into the tube </strong></span></p>
<p>a. Once the new drive is inserted, secure it with 3 screws that were removed in the previous steps. Then, attach the shade bracket in the correct orientation. </p>
<p>Please note: The security screw head and drive buttons should face in the same direction: </p>
<p><img alt='image.png' src='https://lutron.my.salesforce-sites.com/publicknowledge/servlet/rtaImage… style='font-size: 14px;'><strong>3. Reset Upper and Lower Limits</strong></span><br> </p>
Step-by-step instructions on how to remove and install a replacement drive/roller for Sivoia QS shades.